| Specifications |
Catalytic |
Infrared |
OptoAcoustic |
| Operation Principle |
Oxidation |
Absorption |
Acoustic Pressure |
| Signal Drift (Full Scale) |
<5%/year |
<5%/year |
<0.1%/year |
| Accuracy/Repeatability (Full Scale) |
± 5% LEL |
± 5% LEL |
< ± 1% LEL |
| Sensitivity Loss (Gas Consumption) |
High |
Immune |
Immune (Zero Drift) |
| Temperature & Humidity Influence |
Low |
High |
Immune (Zero Drift) |
| Vibration/Moisture/Dust/Wind Influence |
Low |
High |
Immune (Zero Drift) |
| Measurement REDUNDANCY (Backup) |
No |
No |
YES |
| Built-in Plausibility & Self-Diagnostics |
No |
Yes |
YES |
| Linearized/Calibrated (Zero & Span Levels) |
No |
No |
YES |
| Frequency of Faults & False alarms |
Low |
High |
None (self-diagnostics) |
| Sensor Lifetime (Sensor Replacement Cycle) |
< 3 years |
< 7 years |
15 years |
| Operation & Maintenance |
| Recommended Maintenance Cycle |
4x per year |
4x per year |
1x per year |
| Sensor Replacement Cycle |
3 years |
7 years |
None |
| Maintenance Cost Ratio |
88% |
74% |
38% |